Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 2.310
Filter
1.
Organ Transplantation ; (6): 82-89, 2024.
Article in Chinese | WPRIM | ID: wpr-1005237

ABSTRACT

Objective To analyze three-dimensional imaging characteristics and advantages for severe portal vein stenosis after liver transplantation, and to evaluate clinical efficacy of portal vein stent implantation. Methods Clinical data of 10 patients who received portal vein stent implantation for severe portal vein stenosis after liver transplantation were retrospectively analyzed. Imaging characteristics of severe portal vein stenosis, and advantages of three-dimensional reconstruction imaging and interventional treatment efficacy for severe portal vein stenosis were analyzed. Results Among 10 patients, 3 cases were diagnosed with centripetal stenosis, tortuosity angulation-induced stenosis in 2 cases, compression-induced stenosis in 2 cases, long-segment stenosis and/or vascular occlusion in 3 cases. Three-dimensional reconstruction images possessed advantages in accurate identification of stenosis, identification of stenosis types and measurement of stenosis length. All patients were successfully implanted with portal vein stents. After stent implantation, the diameter of the minimum diameter of portal vein was increased [(6.2±0.9) mm vs. (2.6±1.7) mm, P<0.05], the flow velocity at anastomotic site was decreased [(57±19) cm/s vs. (128±27) cm/s, P<0.05], and the flow velocity at the portal vein adjacent to the liver was increased [(41±6) cm/s vs. (18±6) cm/s, P<0.05]. One patient suffered from intrahepatic hematoma caused by interventional puncture, which was mitigated after conservative observation and treatment. The remaining patients did not experience relevant complications. Conclusions Three-dimensional visualization technique may visually display the location, characteristics and severity of stenosis, which is beneficial for clinicians to make treatment decisions and assist interventional procedures. Timely implantation of portal vein stent may effectively reverse pathological process and improve portal vein blood flow.

2.
Article in English | LILACS-Express | LILACS | ID: biblio-1535956

ABSTRACT

Background: Self-expanding metal prostheses improve dysphagia in patients with incurable esophageal cancer (EC). New stents have been introduced, and chemoradiotherapy has been implemented for EC, changing patients' risk profiles. It is unknown whether this has affected palliation with stents. Patients and methods: Retrospective study in three centers in Medellín-Colombia; patients undergoing placement of palliative esophageal prostheses for malignant dysphagia (1997-2022). Major and minor complications after implantation, the influence of oncological therapies, and survival were evaluated for 1997-2009 (n = 289) and 2010-2022 (n = 318). Results: 607 patients underwent esophageal prostheses; 296 (48.8%) became complicated. It was higher in the second period (52.5% vs. 48.1%), as were major complications (20.8% vs. 14.2%, p = 0.033), with no differences in minor complications (33.9% vs 31.8%, p = 0.765). Also, 190 (31.3%) patients presented with recurrent dysphagia, stable in both periods. Migration increased over time (from 13.1% to 18.2%, p = 0.09). The most common minor adverse event was pain, increasing over time (from 24.9% to 33.95%, p < 0.01), and associated factors were chemoradiotherapy, absence of fistula, and squamous cell carcinoma. Acid reflux decreased in the second group (p = 0.038). Twelve percent of patients required another intervention for feeding. Survival was not impacted by time and use of stents. Conclusions: Stents are an alternative in non-surgical malignant dysphagia, although recurrent dysphagia has not decreased over time. Minor stent-related complications are increasing in association with the implementation of chemoradiotherapy.


Antecedentes: Las prótesis metálicas autoexpandibles mejoran la disfagia en pacientes con cáncer esofágico (CE) incurable. En las últimas décadas se han introducido nuevos tipos de stents y se ha implementado la quimiorradioterapia para el CE, generando cambios en los perfiles de riesgo de los pacientes. Se desconoce si estos cambios han afectado la paliación con stents. Pacientes y métodos: Estudio retrospectivo en tres centros de Medellín-Colombia; pacientes sometidos a colocación de prótesis esofágicas paliativas para disfagia maligna (1997-2022). Se evaluaron en dos períodos: 1997-2009 (n = 289) y 2010-2022 (n = 318), complicaciones mayores y menores después del implante, la influencia de las terapias oncológicas y la sobrevida. Resultados: Se evaluaron 607 pacientes sometidos a prótesis esofágicas. 296 (48,8%) se complicaron, y fue mayor en el segundo periodo (52,5% frente a 48,1%), al igual que las complicaciones mayores (20,8% frente a 14,2%, p = 0,033), sin diferencias en complicaciones menores (33,9% frente a 31,8%, p = 0,765). 190 (31,3%) pacientes presentaron disfagia recurrente, estable en ambos períodos. La migración aumentó con el tiempo (de 13,1% a 18,2%, p = 0,09). El evento adverso menor más frecuente fue dolor, que aumentó con el tiempo (de 24,9% a 33,95%, p < 0,01), y los factores asociados fueron quimiorradioterapia, ausencia de fístula y carcinoma de células escamosas. El reflujo ácido disminuyó en el segundo grupo (p = 0,038). El 12% de pacientes requirieron otra intervención para alimentarse. No se impactó la sobrevida con el tiempo y uso de stents. Conclusiones: Los stents son una alternativa en la disfagia maligna no quirúrgica, aunque la disfagia recurrente no ha disminuido con el tiempo. Las complicaciones menores relacionadas con el stent van en aumento, asociadas a la implementación de la quimiorradioterapia.

3.
Rev. colomb. gastroenterol ; 38(3)sept. 2023.
Article in English | LILACS-Express | LILACS | ID: biblio-1535930

ABSTRACT

Introduction: Endoscopic ultrasound (EUS)-guided drainage and luminal-apposing metal stents (LAMS) are the options for managing symptomatic pancreatic pseudocysts. Aim: To evaluate the effectiveness and safety of LAMS for EUS-guided drainage of symptomatic pancreatic pseudocysts in two referral centers in Colombia. Materials and methods: A multicenter prospective cohort study between June 2019 and December 2021 included 13 patients diagnosed with symptomatic pancreatic pseudocysts who underwent EUS-guided drainage with LAMS. Technical success, clinical success, and successful stent removal were evaluated as outcomes. Safety outcomes included stent-related adverse events and general adverse events. Follow-up was carried out for eight weeks, collecting data on stent removal. Results: The average age was 53.4 years; 8/13 were men. The mean size of the pseudocyst was 9.56 ± 2.3 cm. Technical success was 100%, and clinical success was 92.3%. The stents were removed on average after 8 ± 2 weeks. The mean procedural time from puncture to stent deployment was 3.2 ± 2.4 minutes. In the imaging check-up, the collections had adequate drainage in all cases. There was a low frequency of complications; bleeding was documented in one case requiring surgery. Conclusions: LAMS is safe and effective in managing symptomatic pancreatic pseudocysts, reducing hospital stay and cost overruns. Clinical symptomatology prevails in the surgery decision.


Introducción: el drenaje guiado por ultrasonido endoscópico (USE) y el uso de stent metálico luminal de aposición (LAMS) son de elección en el manejo de los pseudoquistes pancreáticos sintomáticos. Objetivo: evaluar la efectividad y seguridad del LAMS para el drenaje por USE de pseudoquistes pancreáticos sintomáticos en dos centros de referencia en Colombia. Materiales y métodos: estudio de cohorte prospectivo multicéntrico entre junio de 2019 y diciembre de 2021, se incluyeron a 13 pacientes con diagnóstico de pseudoquistes pancreáticos sintomáticos sometidos a drenaje por USE con LAMS. Se evaluaron como desenlaces el éxito técnico, el éxito clínico y la extracción exitosa del stent. Y los desenlaces de seguridad incluyeron eventos adversos relacionados con el stent y los eventos adversos generales. Se realizó seguimiento a 8 semanas, en las que se recopilaron datos relacionados con el retiro del stent. Resultados: la edad promedio fue 53,4 años, 8/13 fueron hombres. El tamaño medio del pseudoquiste fue de 9,56 ± 2,3 cm. El éxito técnico fue del 100% y el éxito clínico fue 92,3%. Los stents fueron retirados en promedio a las 8 ± 2 semanas. El tiempo medio del procedimiento desde la punción hasta el despliegue del stent fue 3,2 ± 2,4 minutos. En el control imagenológico hubo un adecuado drenaje de las colecciones en todos los casos. Hubo baja frecuencia de complicaciones, se documentó sangrado en 1 caso con requerimiento quirúrgico. Conclusiones: el uso de LAMS es seguro y efectivo en el manejo de pseudoquistes pancreáticos sintomáticos, disminuye la estancia hospitalaria y sobrecostos. La sintomatología clínica prima en la decisión de intervención.

4.
Article | IMSEAR | ID: sea-220791

ABSTRACT

Extracorporeal Shock Wave Lithotripsy (ESWL) is one of the treatment options for renal and upper ureteric calculus; however, the outcome depends on multiple factors. Our study aims to evaluate the factors that may inuence ESWL outcomes in Indian patients with upper urinary tract calculi. Between 2018 and 2020, a total of 300 adult patients who underwent ESWL for renal and upper ureteral calculus sizing 5 to 20 mm were included in the study program. Patients with

5.
Article | IMSEAR | ID: sea-222287

ABSTRACT

Boerhaave’s syndrome is a potentially fatal condition characterized by spontaneous perforation of a previously healthy esophagus, due to severe vomiting or straining. It often presents with non-specific symptoms such as fever, pain, and vomiting and hence may go undiagnosed. The Makler’s triad, consisting of vomiting, chest pain, and subcutaneous emphysema, may be seen in only 50% of cases. Delayed diagnosis may result in complications such as sepsis, mediastinitis, pneumothorax, and multi-organ dysfunction. In general, patients presenting later than 48 h are conservatively managed with esophageal stenting. Surgical repair is usually reserved for those patients who present within 24 h, or are managed conservatively and develop complications. Mortality rises from 0% if treated within 24 h to about 29% if delayed more than 48 h. We present a case of Boerhaave’s syndrome in a 35-year-old male who presented with spontaneous respiratory distress and hemodynamic instability, about 36 h after the onset of vigorous vomiting. The case was managed initially with endoscopic insertion of a self-expanding metallic stent, followed later by surgical closure of the esophageal perforation. The patient, however, developed post-operative septic complications and died after a week

6.
Chinese Journal of Digestive Surgery ; (12): 260-267, 2023.
Article in Chinese | WPRIM | ID: wpr-990637

ABSTRACT

Objective:To investigate the predictive value of controlled nutritional status (CONUT) score for overt hepatic encephalopathy (OHE) after transjugular intrahepatic portosys-temic stent-shunt (TIPSS) in Budd-Chiari syndrome patients.Method:The retrospective case-control study was conducted. The clinicopathological data of 48 Budd-Chiari syndrome patients who underwent TIPSS in the First Affiliated Hospital of Zhengzhou University from August 2014 to March 2021 were collected. There were 26 males and 22 females, aged (46±13)years. Observation indicators: (1) surgical situations and follow-up; (2) analysis of influencing factors of OHE after TIPSS; (3) predic-tion of OHE after TIPSS. Measurement data with normal distribution were represented as Mean± SD, and comparison between groups was performed using the t test. Measurement data with skewed distribution were represented by M( Q1, Q3), and comparison between groups was performed using the Mann-Whitney U test. Count data were expressed as absolute numbers or percentages, and comparison between groups was performed using the chi-square test or Fisher exact probability. Multivariate analysis was performed using the Logistic regression model with forward method. The receiver operating characteristic (ROC) curve was drawn and the area under the curve (AUC) was calculated to evaluate the efficacy. Comparison among AUC was performed using the Delong test. Results:(1) Surgical situations and follow-up. All 48 patients underwent TIPSS successfully, and the operation time of the 48 patients was (131±29)minutes. All patients were implanted with 8 mm covered stent. All 48 patients were followed up for 46(25,71)months, and there were 14 cases with OHE and 34 cases without OHE after TIPSS. Of the 14 cases with OHE, 12 cases were evaluated as West-Haven Ⅱ grade and 2 cases were evaluated as West-Haven Ⅲ grade. (2) Analysis of influencing factors of OHE after TIPSS. Results of multivariate analysis showed that history of hepatic encephalo-pathy and CONUT score were independent factors influencing the incidence of OHE of Budd-Chiari syndrome patients who underwent TIPSS ( odds ratio=8.36, 1.74, 95% confidence interval as 1.02?68.75, 1.12?2.69, P<0.05). (3) Prediction of OHE after TIPSS. Results of ROC curve showed that the AUC of the CONUT score, the Child-Pugh score of liver function and the integrated model of end-stage liver disease (iMELD) score in predicting the incidence of OHE after TIPSS was 0.77(95% confidence interval as 0.64?0.91, P<0.05), 0.71(95% confidence interval as 0.56?0.87, P<0.05) and 0.71(95% confidence interval as 0.53?0.88, P<0.05), respectively, and there was no significant difference between the AUC of the CONUT score and the Child-Pugh score of liver function or the iMELD score ( Z=0.84, 0.59, P>0.05). The optimal cutoff value of CONUT score in predicting the incidence of OHE after TIPSS was 7, with the sensitivity, specificity and Yodon index as 78.6%, 61.8% and 0.40, respectively. Conclusion:The CONUT score can be used to predict the incidence of OHE in Budd-Chiari syndrome patients who underwent TIPSS, and the discrimination of CONUT score is equivalent to the Child-Pugh score of liver function and the iMELD score.

7.
Journal of International Oncology ; (12): 76-81, 2023.
Article in Chinese | WPRIM | ID: wpr-989524

ABSTRACT

Objective:To explore the efficacy and safety of treating advanced esophageal cancer by implanting the common stent and the radioactive 125I particle stent with endoscope. Methods:The clinical data of patients with advanced esophageal cancer admitted to Jingbian County People's Hospital of Shaanxi Province, the First Affiliated Hospital of Xi'an Medical University, Xijing Hospital of Digestive Diseases of Air Force Medical University and the First Hospital of Yulin of Shaanxi Province from December 2014 to December 2020 were retrospectively analyzed. Patients were divided into common stent group ( n=66) and radioactive particle stent group ( n=34) according to different stent types. The postoperative complications, Karnofsky performance status (KPS) score, dysphagia score, restenosis rate and quality of life were compared between the two groups. Results:The incidences of postoperative retrosternal pain in the common stent group and the radioactive particle stent group were 65.2% (43/66) and 47.1% (16/34) respectively. The incidences of pharyngeal pain and hoarseness were 12.1% (8/66) and 5.9% (2/34) . The incidences of abdominal pain were 9.1% (6/66) and 2.9% (1/34) . The incidences of errhysis were 3.0% (2/66) and 2.9% (1/34) . The incidences of vomiting and nausea were 7.6% (5/66) and 5.9% (2/34) respectively. There were no statistically significant differences between the two groups ( χ2=3.04, P=0.081; χ2=0.40, P=0.527; χ2=0.53, P=0.467; χ2<0.01, P>0.999; χ2<0.01, P>0.999) . In the two groups, KPS scores in the first, second, third and sixth month after operation were higher than those before operation (all P<0.05) . KPS scores of the radioactive particle stent group in the second, third and sixth month were significantly higher than those of the common stent group [ (89.73±7.84) points vs. (82.37±7.42) points, t=4.62, P<0.001; (93.63±8.13) points vs. (88.33±7.28) points, t=3.74, P<0.001; (92.78±6.26) points vs. (87.28±8.73) points, t=3.77, P<0.001]. The dysphagia scores of patients in the two groups in the first, second, third and sixth month were lower than those before operation (all P<0.05) . The dysphagia scores of the radioactive particle stent group in the third and sixth month after operation were significantly lower than those of the common stent group [ (0.68±0.12) points vs. (2.33±0.32) points, t=26.20, P<0.001; (0.82±0.22) points vs. (2.67±0.24) points, t=36.92, P<0.001]. In the third month after operation, the restenosis rate of the radioactive particle stent group was significantly lower than that of the common stent group [5.88% (2/34) vs. 42.4% (28/66) , χ2 =14.27, P<0.001]. The scores of QLQ-C30 and OES-18 scales in the first, second, third and sixth month after operation were lower than those before operation (all P<0.05) . The scores of QLQ-30 scale in the radioactive particle stent group in the second, third and sixth month were significantly lower than those in the common stent group [ (19.12±3.02) points vs. (21.22±2.87) points, t=3.39, P=0.001; (15.04±1.68) points vs. (20.43±2.23) points, t=12.39, P<0.001; (14.38±2.18) points vs. (19.77±3.67) points, t=9.20, P<0.001]. The scores of OES-18 scale in the radioactive particle stent group were also significantly lower than those in the common stent group [ (17.13±2.07) points vs. (20.64±2.11) points, t=7.95, P<0.001; (15.22±1.88) points vs. (19.24±1.76) points, t=10.62, P<0.001; (14.74±2.36) points vs. (18.53±3.27) points, t=6.01, P<0.001]. Conclusion:The radioactive particle stent can improve the quality of life of patients with advanced esophageal cancer with esophageal stenosis, so as to improve dysphagia and reduce the restenosis rate after operation. However, whether it is obviously superior to common stent in prolonging survival time and reducing complications needs to be further confirmed by a multicenter, prospective, large-sample randomized controlled study.

8.
International Journal of Surgery ; (12): 103-107, 2023.
Article in Chinese | WPRIM | ID: wpr-989414

ABSTRACT

Objective:To explore the effect of Quercus Salicina Extract Capsulese on preventing the formation of adherent stones on ureteral stent tube after percutaneous nephrolithotomy (PCNL).Methods:The clinical data of 186 patients who underwent PCNL due to unilateral renal stone in the Affiliated Hospital of Xuzhou Medical University from October 2018 to April 2020 were retrospectively analyzed. All of the patients were indwelling 6 F ureteral stent tube during operation. After postoperative reexamination of kidneys, ureters and bladder, it was confirmed that the postoperative residual stones were clinically meaningless stones (maximum diameter ≤ 4 mm). According to postoperative medication, they were divided into drug group ( n=62) and control group ( n=124). Patients in the drug group were given oral Quercus Salicina Extract Capsules, while patients in the control group did not take the drug. Both groups received the same health education and dietary guidance after operation. The formation of adherent stones on ureteral stent tube was observed when the ureteral stent tube was removed 6 weeks after PCNL. Meanwhile, the adverse reaction, complication and treatment satisfaction of the patients were recorded during the period of taking the drug. Measurement data were expressed as mean ± standard deviation ( ± s), and t-test was used for comparison between groups; the Chi-square test was used to compare the count data between groups. Results:When the ureteral stent tube was removed 6 weeks after PCNL, the weight of adherent stones on ureteral stent tube in the drug group was (334.20±26.65) mg for male, and (336.00±25.64) mg for female. In the control group, the weight of adherent stones on ureteral stent tube was (374.11±42.28) mg for male, (374.42±42.44) mg for female. The weight of adherent stones on ureteral stent tube in the drug group was significantly lighter than that in the control group, and the difference was statistically significant ( P<0.01). The drug group had no obvious serious adverse reaction during the period of taking the drug. At the same time, the complications of the drug group during the intubation period were significantly less than the control group, and the difference was statistically significant ( P=0.040). The satisfaction of patients in the drug group was 93.5%, and that in the control group was 82.3%. The difference was statistically significant between the two groups ( P=0.036). Conclusion:Quercus Salicina Extract Capsules can effectively prevent the occurrence of adherent stones on ureteral stent tube after PCNL, and there are no serious adverse reaction, which is worthy of clinical promotion.

9.
Journal of Medical Biomechanics ; (6): E487-E492, 2023.
Article in Chinese | WPRIM | ID: wpr-987975

ABSTRACT

Objective To explore influences of the taper and connecting rib form on supporting performance of the stent, and provide an important scientific basis for structural design and clinical selection of the tapered stent. Methods A nonlinear finite element model for radial support performance of a novel balloon-expandable tapered stent was constructed, and the radial stiffness (RS) and stress distributions of the stent at different tapers (0°, 0.565°and 1.13°) and with different structural forms of stent linker (V-shape, I-shape, C-shape, S-shape, M-shape) were analyzed by plane compression. The relationship between structural design of the vascular stent and its radial support performance was studied. Results The RS of 0°stent, 0.565°stent, 1.13° stent was 2.51, 1.61, 0.85 N/mm, respectively. The RS of 0.565°stent and 1.13° stent was 35.86% and 66.14% lower than that of 0°stent (round straight stent), respectively. Except that the RS of C-shape linker stent was 1.48 N/mm, the RS of I, M, S and V-shape linker stents was not significantly different, which was 2.51, 2.61, 2.41, 2.52 N/mm, respectively, indicating that radial compression resistance of these four linker stents was almost the same. Conclusions Compared with traditional round straight stents, the RS of tapered stents will decrease, and the RS of stents will gradually decrease with the the taper increasing. Among all stent types in this study, except C-shape linker stents, the RS of other linker shapes has little effect on the RS of stents. The radial support performance of the stent can be improved by reducing the taper of the tapered stent, without changing the form of stent connecting ribs.

10.
Journal of Medical Biomechanics ; (6): E465-E471, 2023.
Article in Chinese | WPRIM | ID: wpr-987972

ABSTRACT

Objective To study the process of single stent and double-stent thrombectomy at the Y-shaped bifurcation of the ideal internal carotid artery by finite element simulation, analyze the stent-thrombus-vessel interaction during the thrombectomy process based on the simulation results, and provide guidance for improving the effect of stent thrombectomy at the bifurcation. Methods The CAD software was used to build the model and the finite element analysis software was used to simulate the process of single stent and double-stent thrombectomy. Results Thrombectomy was unsuccessful in single stent model and successful in double-stent model, and the maximum stress of thrombus during embolus retrieval was twice that of single stent, the maximum strain was 1.12 times that of single stent, and the maximum contact pressure on the surface of vessel was approximately twice that of single stent. Conclusions Double Solitaire stents can effectively prevent thrombus displacement at the bifurcation and successfully retrieve the thrombus, but there is a risk of fracture due to the high stress level in the middle section of the thrombus. The contact pressure of the vessel on the anterior artery side is higher during thrombectomy, and the risk of vessel damage is greater. Therefore, it is necessary to optimize the design of the stent-retriever to improve its flexibility.

11.
Organ Transplantation ; (6): 760-764, 2023.
Article in Chinese | WPRIM | ID: wpr-987129

ABSTRACT

Ureteral stricture in renal allografts is one of the common postoperative complications in kidney transplant recipients. Due to short ureter in renal allografts, endovascular treatment should be adopted before reconstruction surgery to avoid irreversible injury. Alleviating renal allograft injury, easing obstruction or establishing drainage channel are the key measures to treat ureteral stricture. In endovascular treatment, balloon dilatation and internal incision yield high recurrence rate, and long-term indwelling of self-expanding metallic ureteral stents may be a better option. Compared with traditional stents, metallic stents may maintain urinary tract patency for a long time and mitigate the irritation of lower urinary tract symptoms,with different indications and efficacy. Although all metallic stents may be displaced and occluded, it still plays a positive role in the treatment of ureteral stricture in renal allografts. In this article, the application of self-expanding metallic ureteral stent in ureteral stricture of renal allografts was mainly illustrated, aiming to provide reference for optimizing the treatment of ureteral stricture in renal allografts.

12.
Japanese Journal of Cardiovascular Surgery ; : 193-196, 2023.
Article in Japanese | WPRIM | ID: wpr-986344

ABSTRACT

Tracheo-Innominate artery fistula is a rare but devastating complication after tracheostomy. We report a 17-year old man who underwent the transection of the innominate artery and tracheal patch closure (under partial sternotomy) after the endovascular covered stent placement for the recurrent tracheo-innominate artery fistula. Fortunately, his postoperative course was uneventful without any new neurological, bleeding, or infective complication 34 months after the surgery.

13.
Japanese Journal of Cardiovascular Surgery ; : 55-58, 2023.
Article in Japanese | WPRIM | ID: wpr-966096

ABSTRACT

We report the case of a 76-year-old man who developed type IA endoleak through the fenestration after 1-debranch TEVAR using a Najuta endograft. The patient was admitted with expansion of the aneurysm after TEVAR, for additional therapy. Type IA endoleak through a fenestration has remained a significant clinical concern and its treatment is challenging. We performed Zone 0 TEVAR using the “Squid-Capture” technique assisted in situ stent-graft fenestration. Cerebral vessels were perfused by a percutaneous cardiopulmonary support system during in situ stent-graft fenestration, and the cerebral branch was clamped at the proximal site. It is difficult to operate the catheter inside the endoskeleton structure of a Najuta endograft, but several innovations were effective. Test dilation of the balloon catheter was performed to ensure that the wire did not interfere with the endoskeleton. Avoiding interference with the endoskeleton is important. The Squid-Capture technique allows safe and secure puncture of the graft. The operation was completed successfully. After this procedure, the endoleak disappeared. It is considered to be a useful method for treatment of endoleak through the fenestration.

14.
Journal of Clinical Otorhinolaryngology Head and Neck Surgery ; (12): 252-257, 2023.
Article in Chinese | WPRIM | ID: wpr-982727

ABSTRACT

Objective:To evaluate the efficacy of glucocorticoid sinus stents implanted 2 weeks after functional endoscopic sinus surgery(FESS) for the treatment of chronic rhinosinusitis with nasal polyps(CRSwNP). Methods:CRSwNP patients with similar bilateral lesions were randomly divided into two groups, with a stent group of 25 patients and a control group of 24 patients. Patients in the stent group had glucocorticoid sinus stents implanted into the bilateral ethmoid sinuses 2 weeks after FESS, while the control group underwent postoperative debridement only. Follow-up assessments occurred at postoperative weeks 2, 4, 8, and 12. Patients were asked to assess their sensation of nasal symptoms using a 10-point visual analog scale. Efficacy was assessed by endoscopic evaluations. Sinus obstruction, crusting/coagulation, polyp formation, middle turbinate position, adhesions, mucosa epithelialization, and postoperative intervention were assessed as efficacy outcomes. GraphPad Prism 9 was applied for statistical analysis. Results:At 4 and 8 weeks postoperatively, the stent group showed significant improvement in VAS scores of nasal congestion and runny nose compared with the control group(P<0.05). No significant difference was observed in the VAS scores of head and facial stuffiness, loss of smell, or nasal dryness/crusting between the two groups(P>0.05). Compared with the control group, the stent group had a lower rate of polypoid formation at 4, 8, and 12 weeks postoperatively. At postoperative week 12, the rate of mucosal epithelialization in the ethmoid cavity was significantly higher in the stent group. During the follow-up, the frequency of postoperative intervention was significantly lower in the stent group than in the control group(P<0.05). Besides, a lower incidence of middle turbinate lateralization was found in the stent group at 8 and 12 weeks postoperatively. At 8 weeks postoperatively, the stent group had a percentage of adhesion lower than that of the control group(all P<0.05). Conclusion:Implantation of glucocorticoid sinus stents after FESS can maintain sinus cavity patency, improve the inflammatory status of the operative cavity, reduce postoperative interventions, and promote benign regression of the operative cavity.


Subject(s)
Humans , Nasal Polyps/surgery , Ethmoid Sinus/surgery , Glucocorticoids/therapeutic use , Rhinitis/surgery , Sinusitis/surgery , Paranasal Sinuses/surgery , Endoscopy , Stents , Chronic Disease , Treatment Outcome
15.
Journal of Biomedical Engineering ; (6): 552-558, 2023.
Article in Chinese | WPRIM | ID: wpr-981575

ABSTRACT

The interventional therapy of vascular stent implantation is a popular treatment method for cardiovascular stenosis and blockage. However, traditional stent manufacturing methods such as laser cutting are complex and cannot easily manufacture complex structures such as bifurcated stents, while three-dimensional (3D) printing technology provides a new method for manufacturing stents with complex structure and personalized designs. In this paper, a cardiovascular stent was designed, and printed using selective laser melting technology and 316L stainless steel powder of 0-10 µm size. Electrolytic polishing was performed to improve the surface quality of the printed vascular stent, and the expansion behavior of the polished stent was assessed by balloon inflation. The results showed that the newly designed cardiovascular stent could be manufactured by 3D printing technology. Electrolytic polishing removed the attached powder and reduced the surface roughness Ra from 1.36 µm to 0.82 µm. The axial shortening rate of the polished bracket was 4.23% when the outside diameter was expanded from 2.42 mm to 3.63 mm under the pressure of the balloon, and the radial rebound rate was 2.48% after unloading. The radial force of polished stent was 8.32 N. The 3D printed vascular stent can remove the surface powder through electrolytic polishing to improve the surface quality, and show good dilatation performance and radial support performance, which provides a reference for the practical application of 3D printed vascular stent.


Subject(s)
Humans , Stainless Steel , Powders , Cardiovascular System , Constriction, Pathologic
16.
Journal of Peking University(Health Sciences) ; (6): 139-143, 2023.
Article in Chinese | WPRIM | ID: wpr-971286

ABSTRACT

OBJECTIVE@#To assess the safety and efficacy of Neuroform Atlas stent used in treatment of unruptured wide-neck intracranial aneurysms.@*METHODS@#Clinical data of 62 patients with unruptured wide-neck intracranial aneurysms undergoing Neuroform Atlas stent-assisted coiling from August 2020 to September 2021 were retrospectively analyzed. There were 64 aneurysms in those 62 patients. Among them, 25 aneurysms were located at the bifurcation of M1 segment on middle cerebral artery, 16 at the anterior communicating artery, 10 at the C7 segment of internal carotid artery, 5 at the C6 segment of internal carotid artery, 4 at the apex of basilar artery, 3 at the A3 segment of anterior cerebral artery, and 1 at the M2 segment of middle cerebral artery. All the patients underwent Neuroform Atlas stent-assisted coiling, including 49 patients with single stent assisted coiling and 15 patients with dual stents assisted coiling (14"Y"style and 1"X"style). After the procedure, the immediate DSA was performed to evaluate the status of aneurysm occlusion and the parent artery patency. The clinical follow-up was performed 3 months after the operation and evaluated based on the modified Rankin Scale(mRS).DSA image was reviewed at 6 months after operation and Raymond grading scale was used to assess the status of aneurysm occlusion and the parent artery patency.@*RESULTS@#A total of 62 patients with 64 aneurysms were all achieved technical success(100%).The immediate post-procedural Raymond scale was assessed, including Raymond Ⅰ in 57 aneurysms(89.1%, 57/64), Raymond Ⅱ in 6 aneurysms(9.3%, 6/64) and Raymond Ⅲ in 1 aneurysm(1.6%, 1/64). The peri-procedural complications rate was 4.8%(3/62), 2 patients developed intraoperative thrombosis and 1 patient suffered from local subarachnoid hemorrhage. Among them, 55 patients obtained 3 months clinical follow-up after operation and all the patients had good outcomes (mRS≤2), 50 patients with 52 aneurysms were followed up with DSA 6 months after operation, including Raymond Ⅰ in 45 aneurysms(86.5%, 45/52), Raymond Ⅱ in 4 aneurysms(7.7%, 4/52) and Raymond Ⅲ in 3 aneurysms(5.8%, 3/52).@*CONCLUSION@#Neuroform Atlas stent for the treatment of unruptured wide-neck intracranial aneurysms has high safety and good efficacy, and has its advantages over other traditional stents.


Subject(s)
Humans , Intracranial Aneurysm/etiology , Retrospective Studies , Treatment Outcome , Embolization, Therapeutic/methods , Stents/adverse effects , Cerebral Angiography
17.
Clinics ; 78: 100202, 2023. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1439915

ABSTRACT

Abstract Purposes: Braided and laser-cut stents both are efficacious and safe for coiling intracranial aneurysms. The study aimed to compare outcomes following braided stent-assisted coil embolization versus laser engraved stent-assisted coil embolization in 266 patients who were diagnosed with unruptured intracranial aneurysms of different types and locations. Methods: Patients with unruptured complex intracranial aneurysms underwent braided (BSE cohort, n = 125) or laser engraved (LSE cohort, n = 141) stent-assisted embolization. Results: The deployment success rate was higher for patients of the LSE cohort than those of the BSE cohort (140 [99%] vs. 117 [94%], p = 0.0142). Seventy-one (fifty-seven percentages) and 73 (52%) were coil embolization procedure success rates of the BSE and the LSE cohorts. Periprocedural intracranial hemorrhage was higher in patients of the BSE cohort than those of the LSE cohort (8 [6%] vs. 1 [1%], p = 0.0142). Four (three percentages) patients from the LSE cohort and 3 (2%) patients from the BSE cohort had in-stent thrombosis during embolization. Permanent morbidities were higher in patients of the LSE cohort than those of the BSE cohort (8 [6%] vs. 1 [1%], p = 0.0389). Higher successful procedures (76% vs. 68%) and fewer postprocedural intracranial hemorrhage (0% vs. 5%) and mortality (0% vs. 5%) were reported for patients of the BSE cohort in posterior circulation aneurysmal location than those of the LSE cohort. Laser engraved stent has fewer problems with deployment and may have better periprocedural and follow-up outcomes after embolization. Conclusions: Braided stent-assisted embolization should be preferred when the aneurysm is present in the posterior circulation.

18.
J. Transcatheter Interv ; 31: eA202302, 2023. ilus; tab
Article in English, Portuguese | LILACS-Express | LILACS | ID: biblio-1442691

ABSTRACT

Por várias décadas, a revascularização do miocárdio foi considerada o tratamento padrão-ouro de lesões não protegidas do tronco da coronária esquerda. No entanto, a acessibilidade anatômica e o grande calibre dos vasos tornam as lesões de tronco uma opção atraente para a intervenção coronária percutânea. A aplicação dessa intervenção nesse cenário foi expandida ainda mais como resultado da introdução de novos stents farmacológicos, com rápidos avanços em técnicas, dispositivos e farmacoterapias adjuvantes. As evidências atuais têm demonstrado que pacientes com complexidade coronariana baixa ou intermediária têm desfechos similares com a intervenção coronária percutânea ou a revascularização cirúrgica do miocárdio por até 10 anos. O tratamento das lesões da bifurcação do tronco da coronária esquerda continua tecnicamente complexo, apesar dos recentes avanços. A abordagem provisional é a estratégia padrão na maioria dos tipos de lesões da bifurcação do tronco da coronária esquerda. No entanto, algumas lesões complexas da bifurcação do tronco da coronária esquerda justificariam uma técnica eletiva com implante de dois stents. A abordagem integrada, que incorpora técnicas dedicadas, uma avaliação fisiológica e anatômica adjuvante e agentes farmacológicos, é fundamental para abordar com sucesso esse desafio ímpar e melhorar os desfechos clínicos.


For several decades coronary bypass grafting has been considered the gold standard treatment for unprotected left main coronary artery lesions. However, the anatomic accessibility and the large caliber of the vessel render the percutaneous coronary intervention a very attractive treatment option for left main coronary artery lesions. The use of percutaneous coronary intervention in this subset of lesions has been further expanded as a result of the introduction of newer drug-eluting stents along with rapid advancements in techniques, devices, and adjunctive pharmacotherapies. The current evidence has demonstrated that patients with low or intermediate coronary complexity treated with percutaneous coronary intervention or coronary bypass grafting have comparable outcomes, for up to 10 years. Treatment of left main bifurcation lesions remains technically demanding despite recent developments. The provisional approach is the default strategy in most types of left main bifurcation lesions. However, a few complex left main bifurcation lesions would warrant an elective two-stent technique. An integrated approach incorporating custom- tailored techniques, adjunctive physiological and morphologic evaluation, and pharmacologic agents is critical to tackle this unique challenge and improve clinical outcomes.

19.
Clinics ; 78: 100262, 2023. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1520705

ABSTRACT

Abstract Objective Second-generation catheters used in mechanical thrombectomy have different advantages and disadvantages. The objective of this study was to evaluate the effectiveness and safety of the combination of contact aspiration and stent retriever technique on the rate of reperfusion after mechanical thrombectomy for large vessel occlusion. Methods Patients who underwent contact aspiration alone (CAA cohort, n = 150), stent retriever alone (SRA cohort, n = 129), or combined contact aspiration and stent retriever (CSR cohort, n = 122) techniques following mechanical thrombectomy were included in the analysis. A balloon guide catheter was used for all thrombectomies. Digital subtraction angiography was used to identify thrombolysis in cerebral infarction. Results The number of patients with thrombolysis in cerebral infarction score of ≥ 2c (near complete or complete antegrade reperfusion) was significantly higher in the CSR cohort than those in the CAA cohort (101 [83%] vs. 90 [60%], p < 0.0001) and those of SRA cohort (101 [83%] vs. 77 [59%], p = 0.0001). Arterial perforation was higher in patients in the CSR cohort than in those in the CAA (p < 0.0001) and SRA (p = 0.015) cohorts. Intracerebral hemorrhage was lower in patients in the CSR cohort than in those in the CAA (p = 0.0001) and SRA (p = 0.0353) cohorts. All-cause mortality at 1 year was fewer in the CSR cohort than in the CAA cohort (p = 0.018). Conclusions The combination of thrombo aspiration by large bore aspiration catheter and stent retriever is the most effective technique but has some related risks. Level of evidence IV. Technical efficacy stage 1.

20.
Clinics ; 78: 100163, 2023. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1421260

ABSTRACT

Abstract Biliary drainage for Perihilar Cholangiocarcinoma (PCCA) can be performed either by endoscopic retrograde cholangiopancreatography or Percutaneous Transhepatic Biliary Drainage (PTBD). To date there is no consensus about which method is preferred. Taking that into account, the aim of this study is to compare Endoscopic Biliary Drainage (EBD) versus percutaneous transhepatic biliary drainage in patients with perihilar cholangiocarcinoma through a systematic review and metanalysis. A comprehensive search of multiple electronic databases was performed. Evaluated outcomes included technical success, clinical success, post drainage complications (cholangitis, pancreatitis, bleeding, and major complications), crossover, hospital length stay, and seeding metastases. Data extracted from the studies were used to calculate Mean Differences (MD). Seventeen studies were included, with a total of 2284 patients (EBD = 1239, PTBD = 1045). Considering resectable PCCA, the PTBD group demonstrated lower rates of crossover (RD = 0.29; 95% CI 0.07-0.51; p = 0.009 I2 = 90%), post-drainage complications (RD = 0.20; 95% CI 0.06-0.33; p < 0.0001; I2 = 78%), and post-drainage pancreatitis (RD = 0.10; 95% CI 0.05-0.16; p < 0.0001; I2 = 64%). The EBD group presented reduced length of hospital stay (RD = -2.89; 95% CI -3.35 - -2,43; p < 0.00001; I2 = 42%). Considering palliative PCCA, the PTBD group demonstrated a higher clinical success (RD = -0.19; 95% CI -0.27 - -0.11; p < 0.00001; I2 = 0%) and less post-drainage cholangitis (RD = 0.08; 95% CI 0.01-0.15; p = 0.02; I2 = 48%) when compared to the EBD group. There was no statistical difference between the groups regarding: technical success, post-drainage bleeding, major post-drainage complications, and seeding metastases.

SELECTION OF CITATIONS
SEARCH DETAIL